Pentair screenlogic connect not working
Pentair screenlogic connect not working













pentair screenlogic connect not working

The Pentair pool and spa equipment company creates a control system for their system called IntelliTouch and to interface with it via TCP/IP you buy and install their ScreenLogic system. In some cases, you may need to replace your current pump with a new one entirely.Adding a Pentair Screenlogic System to Home Assistant with Docker Summary After power is reconnected if one of these errors continues to reappear, the drive may need service.

pentair screenlogic connect not working

Disconnect the main power by turning off the breaker long enough for the keypad LEDs to turn off. If they do not clear after multiple restart attempts, the drive should undergo a hard power cycle. *17,16, 02, 08, 04, 06, 09, 0A – Internal Errors: These errors can occur based on operating conditions and the UL 60730 required self-diagnostic safety software.

pentair screenlogic connect not working

Otherwise, there could be excess voltage sag caused by improper installation or improper supply voltage.Ġ2 - Absolute Phase current limit exceeded*Ġ8 - Absolute Diode Bridge temperature limit exceeded*Ġ4 - Absolute Power Module temperature limit exceeded*Ġ6 - Absolute Power Factor Correction (PFC) temperature limit exceeded* This could be caused by normal voltage variation and will clear itself. See page 14 “Pump Disassembly” for instructions for disassembling the pump.ĠF – Absolute AC Under-Voltage Detected: This indicates that the supply voltage has dropped below the operating range of 99v. Please disassemble the pump and investigate to see if there is a problem with the impeller or mechanical seal. Ensure that the 5 pin connector is properly plugged into the socket and that there is no damage to the cable.ġA – Power Module over current detected: If this error displays multiple times, then there may be a problem with the pump’s rotating assembly. Decoding the errors on your pumpĢ1 - Communication link between HMI and motor control has been lostĢ1 – Communication Link between the HMI and Motor control has been lost: Check the jacketed wire on the backside of the keypad inside the drive top cover. These codes are a great way to do a simple diagnostic to see what issues your pump is having. Error Codes Key for Pentair Superflo VS Pumpīelow is a list of all the error codes that Pentair has provided for error codes on a Pentair Superflo VS pump.















Pentair screenlogic connect not working